KEEP FOR FUTURE REFERENCE
INSTRUCTIONS
International Version
MODEL NUMBERS: MRT49DC,
MRT4HV11DC, MRT411LDC
SERIAL NUMBER: ___________
(please see serial label and record number here)
MANUAL ROTATOR / TILTER
DC-VOLTAGE
READ ALL INSTRUCTIONS AND WARNINGS
BEFORE OPERATING THIS LIFTER
DESIGNED FOR THE MATERIALS HANDLING PROFESSIONAL
P.O. Box 368 908 West Main
Laurel, MT USA 59044
phone 800-548-7341
phone 406-628-8231
fax 406-628-8354
Vue de la page 0
1 2 3 4 5 6 ... 33 34

Résumé du contenu

Page 1 - INSTRUCTIONS

KEEP FOR FUTURE REFERENCE INSTRUCTIONS International Version MODEL NUMBERS: MRT49DC, MRT4HV11DC, MRT411LDC SERIAL NUMBER: ___________ (please see

Page 2

Rev 26.0/4-13 8 MRT4-DC: #35070 INTENDED USE LOAD CHARACTERISTICS WARNING: This lifter is NOT intended for lifting hazardous materials, such as ex

Page 3 - TABLE OF CONTENTS

Rev 26.0/4-13 9 MRT4-DC: #35070 OPERATING ENVIRONMENT The operator must determine whether the lifter is intended to be used in each work environment

Page 4

Rev 26.0/4-13 10 MRT4-DC: #35070 OPERATION BEFORE USING THE LIFTER The operator must determine whether the lifter is capable of performing each int

Page 5 - SPECIFICATIONS

Rev 26.0/4-13 11 MRT4-DC: #35070 In order to be considered clearly audible, the alarm volume must exceed ambient noise by at least 15 dBA at the ope

Page 6 - WARNINGS

Rev 26.0/4-13 12 MRT4-DC: #35070 Reading the Vacuum Gauge The vacuum gauge indicates the current vacuum level in the lifter’s vacuum system. The gr

Page 7 - OPERATING FEATURES

Rev 26.0/4-13 13 MRT4-DC: #35070 TO LIFT AND MOVE THE LOAD Positioning the Lift Bar WARNING: Lift bar must be oriented vertically to lift load. Nev

Page 8 - ASSEMBLY

Rev 26.0/4-13 14 MRT4-DC: #35070 Monitoring the Low Vacuum Warning Buzzer (if applicable) If the lifter is equipped with a low vacuum warning buzzer

Page 9 - Secondary Rotation Stops

Rev 26.0/4-13 15 MRT4-DC: #35070 TO ROTATE THE LOAD EDGEWISE WARNING: Never disengage both the rotation latch and the tilt latch at the same time.

Page 10 - INTENDED USE

Rev 26.0/4-13 16 MRT4-DC: #35070 TO TILT THE LOAD WARNING: Never disengage both the rotation latch and the tilt latch at the same time This lifter

Page 11 - DISPOSAL OF THE LIFTER

Rev 26.0/4-13 17 MRT4-DC: #35070 AFTER USING THE LIFTER Leave the valve handle in the “RELEASE” position (power off). CAUTION: Do not set the lifte

Page 13 - TO APPLY THE PADS TO A LOAD

Rev 26.0/4-13 18 MRT4-DC: #35070 MAINTENANCE WARNING: Always make sure battery is disconnected before servicing lifter. Note: One or more wiring

Page 14 - Reading the Vacuum Gauge

Rev 26.0/4-13 19 MRT4-DC: #35070 • Keep a written record of all Periodic Inspections. If any deficiency is detected during the inspection, correct i

Page 15 - TO LIFT AND MOVE THE LOAD

Rev 26.0/4-13 20 MRT4-DC: #35070 MAINTENANCE SCHEDULE Unless specified elsewhere in this INSTRUCTIONS manual, the lifter does not require maintenanc

Page 16 - In Case of Power Failure

Rev 26.0/4-13 21 MRT4-DC: #35070 Identify the input voltage marked on the battery charger, and plug it in to an appropriate power source.11 The pow

Page 17 - TO ROTATE THE LOAD EDGEWISE

Rev 26.0/4-13 22 MRT4-DC: #35070 • Filter screen missing from pad face: This screen helps prevent debris from plugging the vacuum hose and the air

Page 18 - TO TILT THE LOAD

Rev 26.0/4-13 23 MRT4-DC: #35070 VACUUM TEST Test the vacuum system for leakage routinely, as directed in the preceding INSPECTION and TESTING SCHED

Page 19 - AFTER USING THE LIFTER

Rev 26.0/4-13 24 MRT4-DC: #35070 AIR FILTER MAINTENANCE (for 1 oz [30 ml] bowl size filters) Filter Function and Conditions Requiring Service An air

Page 20 - MAINTENANCE

Rev 26.0/4-13 25 MRT4-DC: #35070 VACUUM PUMP MAINTENANCE − DYNAFLO DV1032102 WARNING: Before proceeding with any maintenance, disconnect power sour

Page 21 - TESTING SCHEDULE

Rev 26.0/4-13 26 MRT4-DC: #35070 VACUUM PUMP MAINTENANCE − THOMAS 107CDC20 WARNING: Before proceeding with any maintenance, disconnect power source

Page 22 - BATTERY RECHARGE

Rev 26.0/4-13 27 MRT4-DC: #35070 VACUUM SWITCH ADJUSTMENT Vacuum Switch Function17 A vacuum switch controls the low vacuum warning light and the vac

Page 23 - VACUUM PAD MAINTENANCE

Rev 26.0/4-13 1 MRT4-DC: #35070 TABLE OF CONTENTS SPECIFICATIONS ...

Page 24 - Cleaning

Rev 26.0/4-13 28 MRT4-DC: #35070 Adjustment Procedure WARNING: Lifting capacity decreases whenever vacuum switch is adjusted to maintain lower vacu

Page 25 - VACUUM TEST

Rev 26.0/4-13 29 MRT4-DC: #35070 REPLACEMENT PARTS LIST Stock No. Description Qty. 93220 Vacuum Pump - Diaphragm Type - 1-SCFM [28 liters/minute] -

Page 26 - AIR FILTER MAINTENANCE

Rev 26.0/4-13 30 MRT4-DC: #35070 LIMITED WARRANTY Powr-Grip products are carefully constructed, thoroughly inspected at various stages of productio

Page 27 - Replacing the Head Assembly

Rev 26.0/4-13 31 MRT4-DC: #35070

Page 28

Rev 26.0/4-13 32 MRT4-DC: #35070

Page 29 - VACUUM SWITCH ADJUSTMENT

Rev 26.0/4-13 2 MRT4-DC: #35070 MAINTENANCE ...

Page 30 - Adjustment Procedure

Rev 26.0/4-13 3 MRT4-DC: #35070 SPECIFICATIONS Lifter Weight: 130 lbs [59 kg] Power Source: 12 volts DC, 10 amps (with Thomas pump) or 3 amps (with

Page 31 - REPLACEMENT PARTS LIST

Rev 26.0/4-13 4 MRT4-DC: #35070 WARNINGS Powr-Grip is pleased to offer the most reliable vacuum lifters available. Despite the high degree of secu

Page 32 - LIMITED WARRANTY

Rev 26.0/4-13 5 MRT4-DC: #35070 OPERATING FEATURES Note: Components featured in the following instructions for assembling, operating or maintainin

Page 33

Rev 26.0/4-13 6 MRT4-DC: #35070 ASSEMBLY TO SET UP THE LIFTER 1) Open the shipping container and remove all materials for restraining or protectin

Page 34

Rev 26.0/4-13 7 MRT4-DC: #35070 WARNING: Make sure all vacuum hoses are coiled or routed so they cannot become entangled, kinked or punctured durin